Experience, Versatility, Competence - HENGSTLER Hengstler is a leading European manufacturer of industrial components for counting and control applications, such as counters / timers, rotary encoders, industrial and temperature controllers, relays, and printers and cutters. Customers around the globe appreciate our extensive experience and competent service, our broad application know-how and our high flexibility, which is a result of our vast offer of different product variants. Moreover, we can support our customers effectively by offering tailor-made application projects.
Grado 901 - 1/16-DIN PROCESS CONTROLLER CONCISE PRODUCT MANUAL (59222-4) OPERATING MODE NOTE: Set all Configuration Mode parameters and Set Up Mode parameters as desired before starting normal operations. Single Setpoint Operation Dual Setpoint Operation Adjusting Setpoint and Setpoint Ramp Rate Select the display (see above) and then use the Raise and Lower keys to change the displayed value.
Neuigkeiten
NOTE: In Setpoint Strategy 2, the initial display allows setpoint adjustment. Alarm Indication and Status Display When any alarm is active, the ALM indicator will flash and the Alarm Status display may be accessed as follows: Error/Fault Indications These displays appear only if setpoint ramping is not disabled. The Ramping SP value cannot be adjusted and only appears if SP Ramp Rate is not zero. SP Ramp Rate is entered in eng units per hour.
The displays only appear if setpoint ramping is not disabled. The Ramping SP value is not adjustable and only appears if SP Ramp Rate is not zero. SP Ramp Rate is entered in eng units per hour. Manual Control ( = 1 - See SET UP MODE) To select/de-select manual control, press the Auto/Manual key (see right). The SET indicator will flash continuously in Manual Control mode.
The Raise/Lower keys may then be used to adjust the output power. Pre-Tune and Self-Tune Pre-Tune sets the Controllers PID parameters approximately; Self-Tune may then be used to optimise the tuning.
Thermodirektdrucker
To engage: With Controller showing a normal Operator Mode display: HOLD KEYS DOWN UNTIL or For Pre-Tune For Self-Tune To dis-engage: Use same key sequence: NOTE: Pre-Tune will not engage (a) if the setpoint is ramping, (b) if the process variable is within 5% of input span of the setpoint or (c) if the proportional band = 0. It is a single-shot routine and is thus self-disengaging.
Rocket downloading. If = 1 (Auto Pre-Tune enabled - see SET UP MODE), Pre-Tune will run for every power-up. SET UP MODE (SET Indicator ON) NOTE: Set all Configuration Mode parameters as desired before adjusting Set Up Mode parameters.
Entry/Exit PRESS SIMULTANEOUSLY (3 secs) Both displays Flash Three seconds approx. To enter set Up Mode, put the Controller into Operator Mode with normal display, then: To exit Set Up Mode, select the process variable display, then press the keys simultaneously. NOTE: A return is made to Operator Mode if there is no key activity for two minutes. Set Up Mode Parameter Sequence Flashes once Flashing = Pre-Tune engaged ON = Self-Tune engaged If both Pre-Tune and Self-Tune are engaged, AT will flash until Pre-Tune is finished, then turn fully on. Goes OFF SET TO CURRENT LOCK CODE VALUE Displays stop flashing If the upper display does not show the correct Lock Code value when this key is pressed, a return is made to the original Operator Mode display.
Karriere
(Default factory setting = 10.) PRESS Parameter Legend Adjustment Range Default Digital Filter Time Constant OFF, 0.5 to 100.0 secs. Increments 2.0 secs. Process Variable Offset ±span of Controller 0 Output 1 Power Read only N/A Output 2 Power 5 Read only N/A Proportional Band 1 (PB1) 0.0% (ON/OFF Control) to 999.9% of input span 10.0% 1 5 Proportional Band 2 (PB2), 0.0% (ON/OFF Control) to 999.9% of input span 10.0% Reset (Integral Time Constant) 1 1sec. And OFF 5m 00s Rate (Derivative Time Constant) 1 00secs.
We are offering dynapar series hr526 encoder dynapar series hr526 encoder - automate control engineering ltd. Ultra-reliable, heavy duty unbreakable code disk available complete electrical protection and noise immunity up to 1024 ppr with optional marker coupling & flange provide thermal and electrical isolation for the encoder field replaceable coupling typical applications: servo and stepper motor mounting machine tools position tables robotics code: incremental resolution: 1 to 1024 ppr (pulsesrevolution) accuracy: (worst case any edge to any other edge) ±7.5 arc-min. Format: two channel quadrature (ab) with optional index (z) and complementary outputs phase sense: a leads b for cw or ccw shaft rotation as viewed from the shaft end of the encoder; see ordering information quadrature phasing: 90° ± 22.5° electrical symmetry: 180° ± 18° electrical index: 180° ± 18° electrical (gated with b low) waveforms: squarewave with rise and fall times less than 1 microsecond into a load capacitance of 1000 pf.